Memolub Accessories Tech Specs DB

DISTRIBUTOR BLOCKS User guide

Ref. IDs: 2940, 2941, 2942, 2943, 2944, 2945, 2707, 2708, 2709, 2775, 2777

The Memolub distributor block automaticaly supplies fixed quantities of pressurized lubricant to each discharge outlet through the continuous operation of internal pistons, and operate cyclically with a continuous lubricant input.

There are two distributor sizes: one double-stack block dedicated to outlets from 2 to 8, one triple-stack dedicated to outlets from 10 to 12 (see dimensions below). Unused outlets are not threaded. Intermediate number of outlets can be reached by bridging vertical or horizontal outlets together, using the corresponding bridges.

Precautions

  • When assembling the pipes, if there are extra discharge outlets, never block them with a plug.
  • Instead, use a bridge to merge the output of two outlets into one. The pipe connected to this bridge will then have double the dose quantity
  • The indicator rod indicates the normal operation, moving back and forth during one cycle.

Dimensions

DISTRIBUTOR BLOCKS 2-8

2 to 8 outlets

Without sensor
294 X DD DB2 to 8 dimensions

With sensor
294 X DD dimensions DB2 to 8 with sensor

DISTRIBUTOR BLOCKS 10-12

10 to 12 outlets

Without sensor
294 X DD DB10 to 12 dimensions

DISTRIBUTOR BLOCKS 10-12

With sensor
294 X DD dimensions DB10 to 12 with sensor

Dimensions

HORIZONTAL BRIDGE

For distributor block

294 X DD dimensions DB bridge horizontal

VERTICAL BRIDGE

For distributor block

294 X DD dimensions DB bridge vertical

SPECIFICATIONS

TYPE NUMBER OF OUTLETS OUTLET DOSE PER CYCLE [cc] MIN. PRESSURE [bar] MAX. PRESSURE [bar] INLET THREAD OUTLET THREAD MATERIAL REFERENCE
DB2 2 0.3 15 150 BSPT G1/8''F BSP G1/8''F Al 2945
DB4 4 2944
DB6 6 2940
DB8 8 2941
DB10 10 Zn 2942
DB12 12 2943
HORIZ. BRIDGE 1 0.6 BSP G1/8''M 2946
VERT. BRIDGE 2947

WORKING PRINCIPLE

Each pair of outlets consists of a channel with an alternating piston, with a central inlet and additional bifurcations to the next channel. While pushed by the incoming pressurized lubricant, the piston delivers the opposite outlet with the quantity stored in the corresponding portion of the channel. In the same time, the piston opens a bifurcation, propagating the incoming lubricant to the next channel. This sequence repeats until all channels are covered on both sides.

  • 1

    DB working principle 1

  • 2

    DB working principle 2

  • 3

    DB working principle 3